LDS-S20

Leak test system with exchange chambers

The main characteristics are:

  • Fully automatic test sequence according to specified recipes without operator influence
  • Exchange chambers specific for test piece, automatic recognition and recipe allocation
  • Exchange chambers set-up time < 5 min
  • The inner chamber contour is individually manufactured according to customer specifications and test specimen, and therefore future-proof and expandable
  • 1 test piece per test chamber
  • Quality management through certified calibration and process control
  • Secondary workstations are possible
  • Tried and tested standard system with useful equipment options
  • Ergonomic arrangement of the test chamber
  • Chamber size selectable according to customer requirements
  • For the testing of components of different applications
  • Short inspection times through optimised inspection process
  • High suction volume of the pumping unit
  • Standardised modular design enables maximum flexibility
  • Numerous optional accessories (scanner, printer, marker, data management, secondary workstations ...)

Technical data

Double chamber system

Test pieces per chamber 1 piece
System capacity 100 pcs/h
Limit leakage rate typically 9,0 x 10ˉ⁶ mbar l/s
Test gas pressure typically 40 bar helium
Chamber size depending on test piece

We invest in quality!
Our quality management system is
TÜV Rheinland tested and certified.